plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Evaporator Temperature Sensor / Switch|Locations|Page 8599 > < Evaporator Temperature Sensor / Switch|Locations
Page 1
background image

Evaporator Temperature Sensor / Switch: Description and Operation

DESCRIPTION

 The probe monitors the temperature of the refrigerant after expansion.

OPERATION

The probe prevents evaporator freeze-up by signaling the Powertrain Control Module to cycle the compressor ON and OFF. It is a sealed unit and
cannot be adjusted or repaired. It must be replaced if found defective.

CIRCUIT OPERATION

The evaporator temperature sensor is used to monitor the temperature of the evaporator to prevent freeze up. This input is used to control the
operation of the A/C compressor clutch.

Circuit C21 is the feed from the HVAC control to the sensor.

Circuit C57 is used to supply a common ground path for the sensor back to the control. This circuit is spliced and provides a ground path for the
other sensors.

Evaporator Temperature Sensor / Switch|Locations|Page 8599 > < Evaporator Temperature Sensor / Switch|Locations