plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Actuator Calibration and Diagnostics|Page 5013 > < Actuator Calibration and Diagnostics|Page 5011
Page 3
background image

Results:

-

All LED's will turn on for 5 Seconds

-

Cooldown Test is running when A/C and RECIRC. are alternately flashing. If A/C and RECIRC. are flashing simultaneously, Cooldown has
failed.

Calibration Diagnostics And Cooldown Abort

Test can be aborted by doing one of the following:

-

Depressing Rear Window Defogger, RECIRC and Rear Wiper buttons.

-

Cycling Ignition OFF and then ON.

-

Control will automatically abort after 15 minutes from the time Calibration Diagnostics and Cooldown was entered.

The HVAC control module will return to normal operation or may indicate unsuccessful Calibration.

Diagnostics or Cooldown test by LED's flashing simultaneously.

Actuator Calibration and Diagnostics|Page 5013 > < Actuator Calibration and Diagnostics|Page 5011