plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Fillpipe Restrictor > < Thermal Vacuum Valve, EGR|Locations|Page 2753
Page 1
background image

Thermal Vacuum Valve: Service and Repair

Thermo Valve Location

REMOVAL

CAUTION: Vacuum fittings on the valve are easily broken. Use care upon removal.

1.

Drain approximately 1 gallon of coolant from the radiator drain plug.

2.

Mark and remove the vacuum hoses from the valve.

3.

Using a suitable socket, remove the valve.

INSTALLATION

1.

Clean and dry the threads on the thermo valve and on the engine.

2.

Apply sealant to the threads of the thermo valve.

Specified sealant

3M NUT Locking Part No. 4171 or equivalent.

3.

Install and torque the thermo valve.

Torque value

15 - 30 ft.lbs (20 - 40 Nm)

4.

Reconnect the vacuum hoses.

5.

Refill the cooling system and check for leaks.

Fillpipe Restrictor > < Thermal Vacuum Valve, EGR|Locations|Page 2753