plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Evaporative Check Valve > < Initial Inspection and Diagnostic Overview|Page 2974
Page 1
background image

Canister Purge Solenoid: Service and Repair

Fig. 101 Upstream Heated Oxygen Sensor Removal/Installation & EVAP Purge Solenoid Location

NOTE:  The solenoid attaches to a bracket near the front engine mount. The solenoid will not operate unless it is installed correctly

REMOVAL

1. Disconnect electrical connector from solenoid.
2. Disconnect vacuum tubes from solenoid.
3. Remove solenoid from bracket.

NOTE:  The top of the solenoid has TOP printed on it. The solenoid will not operate unless it is installed correctly.

INSTALLATION

1. Install solenoid on bracket.
2. Connect vacuum tube to solenoid.
3. Connect electrical connector to solenoid.

Evaporative Check Valve > < Initial Inspection and Diagnostic Overview|Page 2974