Power Door Lock Switch: Description and Operation
Right Door Switch Operation

Lock

CIRCUIT OPERATION

When the switch is moved to the LOCK position,voltage is supplied to the P33 circuit, and then to the door lock motors. The ground path is
provided on the P34 circuit back to the right door switch. The ground is passed through the switch internal bus bar to the P36 circuit. The P36
circuit connects to the left door switch and through to the Z8 circuit. The Z8 circuit then connects to the grounding point at the left center
instrument panel support.

Unlock

CIRCUIT OPERATION

When the switch is moved to the UNLOCK position voltage is supplied to the P34 circuit from the switch to the door UNLOCK side of the
motors. The grounding path is through the LOCK side of the motors, circuit P33, back to the switch. The ground continues through the internal
bus bar of the switch on circuit P35 to the left door switch. At the left door switch, the ground passes through that switches internal bus bar to the
Z8 grounding point.