Air Door Cable: Adjustments
Mode Control Cable Adjustment

1. Attach cable to actuator arm on mode door and clip black casing against the stop.
2. Attach other end of cable to instrument panel control.
3. Turn the mode knob completely counterclockwise.
4. While holding the knob in the counterclockwise position, pull on the black casing of the mode cable. This will take up any free play in the cable

and index the mode door to the mode knob.

5. Then snap the cable hold down clip into position.