WARNING:  Do not allow ohmmeter to contact terminals 85 or 86 during this test.

7. Attach the other end of the jumper wire to relay terminal 86. This activates the relay. 

-

The ohmmeter SHOULD show continuity between relay terminals 87 and 30. 

-

The ohmmeter SHOULD NOT show continuity between relay terminals 87A and 30.

8. Disconnect jumper wires.

Replace the relay if it did not pass the continuity and resistance tests. If the relay passed the tests, it operates properly Check the remainder of the ASD
and fuel pump relay circuits. Refer to electrical diagrams.