Air Door Cable: Adjustments
Recirculation Door Cable Adjustment

Fig 41  Recirculation Door Cable

RECIRCULATION DOOR CABLE

Notes:

-

The RECIRC door is actuated by a cable which mechanically positions the door. The cable is not serviced.

-

The cables must be adjusted for proper function of the control module. 

To adjust the cable: 

1. Attach the cable to the lever arm of the control module. 
2. Turn the knob fully counterclockwise. 
3. Pull the cable jacket away from the cable end until taut. 
4. Clip the cable jacket to the control module. 

The knob should travel a full 180 ° if the cable is properly adjusted.