Workshop Repair Manuals

Plymouth Workshop Manuals

[PREV PAGE] [NEXT PAGE]

plymouth Workshop Repair Guides


Prowler V6-3.5L VIN G (1999)

Heating and Air Conditioning > Air Door, HVAC > Air Door Cable, HVAC > Component Information > Adjustments > Recirculation Door Cable Adjustment

Page 1
background image

Air Door Cable: Adjustments
Recirculation Door Cable Adjustment

Fig 41  Recirculation Door Cable

RECIRCULATION DOOR CABLE

Notes:

-

The RECIRC door is actuated by a cable which mechanically positions the door. The cable is not serviced.

-

The cables must be adjusted for proper function of the control module. 

To adjust the cable: 

1. Attach the cable to the lever arm of the control module. 
2. Turn the knob fully counterclockwise. 
3. Pull the cable jacket away from the cable end until taut. 
4. Clip the cable jacket to the control module. 

The knob should travel a full 180 ° if the cable is properly adjusted.

Heating and Air Conditioning > Air Door, HVAC > Air Door Cable, HVAC > Component Information > Adjustments > Recirculation Door Cable Adjustment

[PREV PAGE] [NEXT PAGE]