plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Leak Detection Pump, Evaporative System|Service and Repair > < Emissions - Evaporative Emissions Manual Revisions|Page 2607
Page 4
background image

the place of the ultrasonic leak detector 6917A. The EELD utilizes shop air and a smoke generator to visually detect leaks down to 0.020 or smaller. The
food grade oil used to make the smoke includes an UV trace dye that will leave telltale signs of the leak under a black light. This is helpful when
components have to be removed to determine the exact leak location. For detailed test instructions, follow the operators manual packaged with the
EELD.

IMPORTANT

Be sure that the PCM has the latest software update. Reprogram as indicated by any applicable Technical Service Bulletin. After LDP repairs are
completed, verify the repair by running the DRB Ill® Leak Detection Pump (LDP) Monitor Test as described in Technical Service Bulletin 18-12-99.

Leak Detection Pump, Evaporative System|Service and Repair > < Emissions - Evaporative Emissions Manual Revisions|Page 2607