Sundance L4-135 2.2L SOHC (1987)
Jumper Wire Connections
1.
Unplug wiring harness. Connect jumper wire between motor terminals "P2" and "L."
2.
Connect a second jumper wire from terminal "P1" to battery. If motor runs to park position and stops, switch is faulty. If motor keeps running and
does not park, replace motor assembly.
Motor Only Runs at High or Low Speed
Wiper Motor Wiring Connectors
NOTE: To gain access to wiper motor wiring terminals, remove terminal cover or suppressor as required.