Page 7
background image

1. Install the right hand temperature actuator.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the right hand temperature actuator mounting screws.

Tighten
Tighten the screws to 1.6 N.m (14 lb in).

3. Connect the right hand temperature actuator electrical connector.

IMPORTANT:  Align the pin on the right hand air temperature actuator with the slot in the right hand temperature door lever.

4. Install the right hand temperature lever (1) to the right hand temperature door.
5. Connect the right hand temperature door lever spring (2) to the right hand temperature door lever (1) and HVAC module case.
6. Install the I/P compartment.
7. Recalibrate the actuators. Refer to Re-Calibrating Actuators.

Mode Actuator Replacement