pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Solar Sensor, HVAC|Locations|Page 7566
Page 1
background image

Service Port HVAC: Service and Repair

SERVICE PORTS REPLACEMENT

TOOLS REQUIRED

-

J 39037 Charge Valve Octagon Socket

-

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Remove the service port cap.
2. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.

3. Use the J 39037 to remove the service port.

INSTALLATION PROCEDURE

1. Lightly coat the O-ring with mineral base 525 viscosity refrigerant oil.

IMPORTANT:  DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the new O-ring to enter the refrigerant system.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the service port.

Tighten
Tighten the service port to 11 N.m (98 lb in).

3. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
4. Leak test the fittings of the component using J 39400-A.
5. Install the service port cap. Tighten the cap 1/4-1/2 turn after the seal washer contacts to access fitting.

Solar Sensor, HVAC > < Solar Sensor, HVAC|Locations|Page 7566