pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Control Module HVAC|Service and Repair > < Blower Control Module|Page 7778
Page 1
background image

Control Module HVAC: Adjustments

Programmer Assembly & Temperature Valve Link

1. Pull valve link from retainer on programmer output crank (if not previously disassembled). Crank can be accessed through glove box area on

vehicles not equipped with driver/passenger SIR. 

2. Start car; set fan to HI and temperature to 33°C (90°F). If ambient temperature is above 33°C (90°F), disconnect in-vehicle temperature sensor.

3. Allow 45 seconds minimum for programmer motor to move output crank to its full hot position. Then move temperature valve to full hot position;

snap valve link into retainer on output crank.

Control Module HVAC|Service and Repair > < Blower Control Module|Page 7778