Bonneville V6-3800 3.8L Supercharged (1992)
![background image](/pontiac/bonneville/v6-3800_3.8l_supercharged/Page-3073003.png)
Chart A1 Windshield Perimeter Leaks
A suspected leak in the windshield urethane seal should be confirmed in the shop using one of the several static test methods. An ultrasonic tester such as
Kent Moore J26419 or Snap-On AC6600 is preferred, but any method, that can pinpoint the exact leak location, will save valuable time.
Repair Method: