Oxygen Sensor: Description and Operation

The oxygen sensor--mounted in the exhaust system ahead of the catalytic converter--provides a varying DC voltage to the ECM representing the
oxygen content of the exhaust gas. 
-

When the fuel mixture is lean sensor voltage is low--under 0.2 volts--.

-

When the fuel mixture is rich sensor voltage is high--up to 1 volt--. 

The ECM uses these signals to control Mixture Control (MC) solenoid operation.

NOTE:  Voltage signals are not supplied by the sensor until exhaust temperature reaches 600° F. 