pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Service and Repair
Page 2
background image

Tighten
Tighten the accumulator bracket bolt to 6 N.m (53 lb in).

5. Install the accumulator hose bracket nut (1) to the strut tower.

Tighten
Tighten the accumulator hose bracket nut (1) to 8 N.m (71 lb in).

6. Install the accumulator bolt (2) to the module.

Tighten
Tighten the accumulator bolt (2) to 16 N.m (12 lb ft).

7. Install the A/C compressor hose assembly bolt to the accumulator.

Tighten
Tighten the A/C compressor hose assembly bolt to 16 N.m (12 lb ft).

8. Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
9. Leak test the fittings of the component using the J 39400-A.

Air Door, HVAC > < Accumulator HVAC|Service and Repair