G6 L4-2.4L VIN B (2006)
1. Clean the sealing surface of the BPMV with denatured alcohol and a clean shop cloth.
2. Use care when aligning the EBCM to the BPMV electrical terminals. Install the EBCM to the BPMV.
3. Notice: Refer to Fastener Notice in Service Precautions.
Install the 4 EBCM-to-BPMV retaining bolts (1). Tighten the bolts in a criss-cross pattern.
Tighten the bolts to 5 Nm (44 inch lbs.).
4. Important: Ensure that the electrical connector is correctly inserted into the EBCM prior to swinging the assist locking lever into position.
Failure to make a proper connection may cause communication problems with the module.