G6 V6-3.6L (2007)
1. Clean the sealing surface of the BPMV with denatured alcohol and a clean shop cloth.
2. Use care when aligning the EBCM to the BPMV electrical terminals . Install the EBCM to the BPMV.
Notice: Refer to Fastener Notice .
3. Install the 4 EBCM-to-BPMV retaining bolts (1). Tighten the bolts in a criss-cross pattern.
Tighten the bolts to 5 N.m (44 lb in).
Important: Ensure that the electrical connector is correctly inserted into the EBCM prior to swinging the assist locking lever into
position. Failure to make a proper connection may cause communication problems with the module.