G6 V6-3.6L (2007)
Variable Valve Timing Solenoid: Service and Repair
Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Exhaust
CAMSHAFT POSITION ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 2 (LEFT SIDE) EXHAUST
Removal Procedure
1. Remove the air cleaner assembly.
2. Remove the engine mount strut bracket.
3. Disconnect the engine wiring harness electrical connector (4) from the bank 2 exhaust camshaft position (CMP) actuator solenoid valve.
4. Remove the CMP actuator solenoid valve bolt.
5. Remove the CMP actuator solenoid valve.
6. Inspect the CMP actuator solenoid valve seal for damage and replace as necessary.
Installation Procedure