G6 V6-3.6L (2007)
Pressure Regulating Solenoid: Service and Repair
4T45-E - Automatic Transaxle
Pressure Control Solenoid Replacement
Removal Procedure
Important: Retainer clips hold in each of the valve line-ups. Use a small screwdriver in order to remove the retainer clips. Be careful not to
score the valve body when removing the retainer clips and valves. Before removing the valve line-ups, inspect each valve line-up for freedom of
movement.
1. Remove the transmission side cover.
2. Remove the Pressure Control Solenoid (PCS) retainer clip (304), the PCS with two O-rings and screen (312, 309, 310), the torque signal regulator
valve (309), and the torque signal regulator spring (308).
Installation Procedure
1. Install the torque signal regulator spring (308), the torque signal regulator valve (309), the Pressure Control Solenoid (PCS) with two O-rings and
screen (312, 309, 310) and the PCS retainer clip (304).
2. Install the transmission side cover.
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will need to
relearn TAP values. Transmission performance may be affected as new TAP values are learned.
3. Reset the TAP values. Refer to Transmission Adaptive Functions.