18. Connect the RF brake pipe fitting (1).
Tighten the fitting to 20 Nm (15 lb ft).
Note: Ensure the electrical connector is correctly inserted into the EBCM prior to placing the locking lever into position. Failure to make a proper
connection may cause communication problems with the module.
19. Connect the EBCM electrical connector.
20. Bleed the hydraulic brake system. Refer to Hydraulic Brake System Bleeding (Manual) (See: Brake Bleeding/Service and Repair)Hydraulic
Brake System Bleeding (Pressure) (See: Brake Bleeding/Service and Repair).
21. Calibrate the brake pedal position sensor. Refer to Brake Pedal Position Sensor Calibration (See: Lighting and Horns/Brake Light Switch/Service
and Repair/Brake Pedal Position Sensor Calibration).