5. Install the suction hose and liquid line to the TXV.

Caution:  Refer to Fastener Caution   (See: Service Precautions/Vehicle Damage Warnings/Fastener Caution).

6. Install the suction hose and liquid line nut to the TXV and tighten the nut to 20 Nm (15 lb ft).
7. Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging   (See: Heating and Air Conditioning/Service and

Repair/Procedures/Refrigerant Recovery and Recharging).

8. Leak test the fittings using the J 39400-A  .
9. Install the surge tank to the surge tank bracket.