18. Disconnect the suction pipe upper (1) from suction pipe lower (2).
Important: The sealing washer (3) is a single use item and must be discarded after use.
19. Remove the sealing washer (3). Refer to Sealing Washer Replacement (See: Coupler HVAC/A/C Coupler O-ring/Service and Repair/Sealing
Washer Replacement) .
Discard the sealing washer
Important: Cover any opening of the A/C system with a suitable cap or tape immediately, to prevent absorption of moisture from the
atmosphere.
20. Cap or plug the suction pipe upper (1) and the suction pipe lower (2).
21. Remove the suction pipe/liquid pipe pad to TX valve retaining nut (1).