29. Disconnect the suction pipe/liquid pipe pad (3) from the TX valve (1).
Important: The sealing washers (2) are a single use item and must be discarded after use.
30. Remove the sealing washers (2). Refer to Sealing Washer Replacement (See: Heating and Air Conditioning/Coupler HVAC/A/C Coupler
O-ring/Service and Repair/Sealing Washer Replacement) .
Discard the sealing washers
Important: Cover any opening of the A/C system with a suitable cap or tape immediately, to prevent absorption of moisture from the
atmosphere.
31. Cap or plug the suction pipe (4), liquid pipe (5) and the TX valve (1).
32. Remove the liquid pipe (5) from the suction pipe/liquid pipe pad (3).
33. Detach the suction pipe (2) and the liquid pipe (3) from the suction pipe/liquid pipe retaining clip (1).
34. Remove the suction pipe (2) from the engine compartment.
Installation Procedure