Grand AM L4-121 2.0L (1988)
Service Port HVAC: Technical Service Bulletins
A/C - O-Ring Push Out During Switch Installation
Bulletin Number:
90-1-1
Reference Number:
971206
Publish Date:
9/89
SERVICE PROCEDURE O-RING PUSH OUT
Subject:
DURING HI SIDE SWITCH INSTALLATION
Models
Affected:
1988-90 GRAND AM AND SUNBIRD MODELS WITH C60
Due to a stack up of tolerances between the high side pressure switch or sensor and the high side port, some difficulty may be encountered when
replacing a switch or sensor with the refrigerant system charged. The Schraeder (R) valve may be depressed before the O-ring is captured by the switch
resulting in the O-ring being pushed out of its sealing area causing a leak.
On vehicles with this condition, the O-ring may be held in place by wrapping a string around the inboard side of the switch port while the switch is being
screwed on (refer to Figure 1). This will hold the O-ring in the switch port while the Schraeder (R) valve is being depressed. Once the O-ring is captured,
the string should be removed and the switch screwed on until fully seated. The joint should then be leak checked with a refrigerant detector.
Redesigned parts will be in production during the 1990 model year.