Grand AM V6-3.4L VIN E (2001)
3. Prepare the splice Untwist the conductors and follow the splicing instructions for copper wire. Staggering the splices by 65 mm is recommended.
4. Re-assemble the cable.
^
Rewrap the conductors with the mylar tape.
^
Use caution not to wrap the drain wire in the tape (1).
^
Follow the splicing instructions for copper wire and splice the drain wire.
^
Wrap the drain wire around the conductors and tape with mylar tape.
IMPORTANT: Apply the mylar tape with the aluminum side inward. This ensures good electrical contact with the drain wire.