2. If removed, install the water outlet.
3. Install the water outlet bolts.

^

Tighten the water outlet bolts to 25 Nm (18 ft. lbs.).

NOTICE:  Refer to Fastener Notice in Service Precautions.

4. If removed, install the Engine Coolant Temperature (ECT) sensor.

^

Tighten the ECT sensor to 23 Nm (17 ft. lbs.).

5. Apply 8 - 12 mm (0.08 - 0.11 inch) bead of RTV Sealer, GM P/N 12345739 or equivalent, on each ridge where front and rear of the lower intake

manifold contact the engine block (1).

6. Install the lower intake manifold gaskets.