Control Module HVAC: Service and Repair

Remove or Disconnect

1. Right side instrument panel insulator. 
2. Electrical connectors from blower motor control module.
3. Loosen (do not remove) both forward mounting screws.

^

Blower motor control module opening is slotted as access is extremely limited.

4. Rearward mounting screw.
5. Blower control module.

Important
^

Care must be taken when removing the blower motor control module. The resistor is a ceramic card for (C60).

Install or Connect

1. Blower motor control module.
2. Rearward mounting screw.

Tighten
^

Screw to 1.5 N.m (13 lb. in.).

3. Tighten both forward mounting screws.

Tighten
^

Screws to 1.5 N.m (13 lb. in.).

4. Electrical connectors to blower motor control module.
5. Right side instrument panel insulator. 