Air Duct: Customer Interest
A/C Outlets, Left - Condensation in Pocket Areas

Group Ref.: HVAC

Bulletin No.: 431202

Date: January, 1994

SUBJECT:
CONDENSATION ACCUMULATES IN POCKET AREAS ABOVE A/C OUTLETS 
(REPLACE CENTER AND LEFT A/C OUTLET SEALS)

MODELS:
1994 PONTIAC GRAND PRIX

CONDITION:
Some customers may notice water accumulating in the pocket areas above the left and center air conditioning (A/C) outlets.

CAUSE:

Under certain high humidity conditions, cold air leakage between the upper A/C outlet seal and instrument panel pocket area causes moisture to
condense.

CORRECTION:

1.

Remove instrument panel accessory trim plate.

2.

Remove instrument panel cluster the plate.

3.

Remove center and left side A/C outlet seals.

4.

Replace with new seals. Part numbers are as follows:

Center A/C Outlet Seal

1675-4589

Left Side A/C Outlet Seal

16754590