Grand Prix V6-3100 3.1L MFI VIN M (1994)
Air Duct: Customer Interest
A/C Outlets, Left - Condensation in Pocket Areas
Group Ref.: HVAC
Bulletin No.: 431202
Date: January, 1994
SUBJECT:
CONDENSATION ACCUMULATES IN POCKET AREAS ABOVE A/C OUTLETS
(REPLACE CENTER AND LEFT A/C OUTLET SEALS)
MODELS:
1994 PONTIAC GRAND PRIX
CONDITION:
Some customers may notice water accumulating in the pocket areas above the left and center air conditioning (A/C) outlets.
CAUSE:
Under certain high humidity conditions, cold air leakage between the upper A/C outlet seal and instrument panel pocket area causes moisture to
condense.
CORRECTION:
1.
Remove instrument panel accessory trim plate.
2.
Remove instrument panel cluster the plate.
3.
Remove center and left side A/C outlet seals.
4.
Replace with new seals. Part numbers are as follows:
Center A/C Outlet Seal
1675-4589
Left Side A/C Outlet Seal
16754590