pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Fuel Pressure Regulator|Specifications|Page 5363 > < Fuel Pressure Regulator|Specifications|Page 5361
Page 1
background image

Fuel Pressure Regulator: Service and Repair

Fuel Pressure Regulator Service

REMOVE OR DISCONNECT

1. Perform Fuel Pressure Release procedure. 
2. Remove the upper intake manifold.  
3. Remove the fuel pressure regulator vacuum line.
4. Remove the fuel pressure regulator retaining screw.
5. Using a shop towel to catch any spilled fuel, lift and twist the fuel pressure regulator in order to remove the fuel pressure regulator from the fuel

rail.

6. Remove the retainer and spacer bracket from rail and discard.
7. Remove the fuel pressure regulator from engine fuel return pipe.
8. Remove the fuel pressure regulator inlet O-Ring and discard.

INSTALL OR CONNECT

    
WARNING: The fuel return line must be connected before tightening the regulator attaching screw to prevent the regulator from rotating.
Rotation of the regulator could damage the retainer and spacer bracket and lead to a fuel leak at the regulator inlet.

    

CAUTION:
^

Compressed air must never be used to test or clean a fuel pressure regulator, as damage to the fuel pressure regulator may result.

^

If needed, the fuel pressure regulator filter screen should be cleaned with gasoline.

^

The fuel pressure regulator should not be immersed in solvent in order to prevent damage to the fuel pressure regulator.

1. Filter screen for contamination. If contaminated, remove and discard filter screen.
2. Lubricate new pressure regulator inlet O-Ring with clean engine oil and install on regulator inlet.
3. Install the fuel return pipe to regulator.
4. Install the new retainer and spacer bracket into slot on fuel rail.
5. Install the pressure regulator to fuel rail.

Tighten
Nut to 17 Nm (13 lb. ft.).

6. Install the fuel pressure regulator vacuum line.
7. Install the pressure regulator attaching screw. 

Tighten
Screw to 8.5 Nm (76 lb in.).

8. Inspect and verify that retainer and spacer bracket is engaged in slots in fuel rail. Grasp and pull on regulator to ensure that it is properly seated.
9. Install the upper intake manifold. 

10. Install the fuel filler cap.
11. Check for fuel leaks.

-

Turn ignition to ON position for 2 seconds.

-

Then turn to OFF for 10 seconds.

-

Turn the ignition to ON position.

Fuel Pressure Regulator|Specifications|Page 5363 > < Fuel Pressure Regulator|Specifications|Page 5361