pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Control Valve and Manifold|Page 7700 > < Control Valve and Manifold|Page 7698
Page 8
background image

1. Install new boot clamp onto boot.
2. Apply grease to inner tie rod or housing as shown in Fig. 16.
3. Align and install breather tube.
4. Install boot onto housing until seated in housing groove tang.
5. Position boot clamp on boot and crimp.
6. Position tie rod end clamp on boot and secure with pliers.

Pinion and Valve Assembly

Fig. 20  Rack Bearing Removal

Control Valve and Manifold|Page 7700 > < Control Valve and Manifold|Page 7698