pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Restraint Systems > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 7312
Page 1
background image

Service Port HVAC: Service and Repair

TOOLS REQUIRED

-

J 39037 Charge Valve Octagon Socket

-

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Remove the service port cap.
2. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.

3. Use the J 39037 to remove the service port.

INSTALLATION PROCEDURE

1. Lightly coat the O-ring with mineral base 525 viscosity refrigerant oil.

2. Install the service port.

IMPORTANT:DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the new O-ring to enter the refrigerant system.

NOTE: Refer to Fastener Notice in Service Precautions.

See: Service Precautions/Vehicle Damage Warnings

Tighten
Tighten the service port to.....11 N.m (98 lb in).

3. Evacuate and recharge the A/C system. 
4. Leak test the fittings of the component using J 39400-A.
5. Install the service port cap.

Tighten the cap 1/4-1/2 turn after the seal washer contacts to access fitting.

Restraint Systems > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 7312