background image

Important:   DO NOT allow any of the mineral base 525 viscosity oil on the NEW O-ring to enter the refrigerant system.

1. Lightly coat the NEW O-ring seal with mineral base 525 viscosity refrigerant oil.
2. Install the O-ring seal (3) onto the valve if necessary.

Notice:  Refer to Fastener Notice.

3. Install the A/C refrigerant valve (2).

Tighten the valve to 11 N.m (98 lb in).

4. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
5. Leak test the fitting valve area using the J 39400-A.
6. Install the service port cap (1).

Restraint Systems > < Service Port HVAC|Service and Repair