Montana SV6 FWD V6-3.5L VIN L (2005)
43. Bend flat the twisted connection.
44. Secure and insulate the 3-wire connection to deployment harness using electrical tape.
45. Twist together the two connector wire leads of the low circuits from both stages of the I/P module to the deployment harness wire. Refer to SIR
Connector End Views in order to determine the correct circuits.
46. Ensure the 3-wire connection is secure.
47. Bend flat the twisted connection.
48. Secure and insulate the 3-wire connection to deployment harness using electrical tape.
49. Connect the deployment harness to the I/P module in-line connector.