Parisienne V6-262 4.3L (1986)
Removing Master Cylinder Reservoir
7. Clamp master cylinder in a vise, then remove reservoir using a pry bar. Remove reservoir grommets.
CAUTIONS:
^
Do not clamp on master cylinder body, instead clamp on mounting flange.
^
Do not remove quick take-up valve from body. The valve is not serviceable separately.
8. Inspect master cylinder bore for corrosion.
NOTE: Do not use abrasive material on master cylinder bore. Replace if bore is corroded.