pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

All Technical Service Bulletins for Instrument Panel Control Module: > < Control Module HVAC|Locations|Page 461
Page 1
background image

Instrument Panel Control Module: Customer Interest
Engine Controls/Instruments - Fuel Gauge Fluctuation

TECHNICAL

Bulletin No.: 08-06-04-013

Date: March 04, 2008

Subject: 
Fuel Gage Fluctuates On Acceleration or Sharp Turns Low Fuel Light Illuminated (Reprogram I/P and ECM)

Models:
2006-2007 Pontiac Solstice
2007 Saturn Sky
2007 Daewoo G2X

Condition

Some customers may comment on fuel gage fluctuation on acceleration or sharp turns when their fuel gage is at or below 1/4 tank level or above 3/4
level. The needle may fluctuate between 1/8 and empty and eventually turn the low fuel light on. The needle will return to proper level after a few
seconds.

Correction

DO NOT replace the fuel tank module or the fuel level sensor.

Technicians are to reprogram the I/P and ECM simultaneously using Sequential Programming.

A revised calibration has been developed to address this issue. Reprogram the I/P and ECU with an updated software calibration using the Service
Programming System (SPS). This new service calibration is available on TIS2WEB . As always make sure your Tech 2(R) is updated with the latest
software version.

These calibrations will be available as an ECM/IPC programming sequence event.

Important:

Technicians have to select ECM/IPC Sequential Programming in the Supported Controllers Screen

Warranty Information

Important:

Currently, the Service Programming System does not generate a warranty claim code after a sequential programming event, when both the IPC and
ECM are programmed in the same session. Until the proper codes are generated by the SPS, please use ZZ999 to indicate a sequential programming
event. A Warranty Claim Code of "ZZ999" must be submitted on all warranty claims in which the vehicle was reprogrammed.

For vehicles repaired under warranty, use the table.

Disclaimer

All Technical Service Bulletins for Instrument Panel Control Module: > < Control Module HVAC|Locations|Page 461