pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Procedures|Page 784 > < Pedal Positioning Sensor|Diagrams
Page 1
background image

Pedal Positioning Sensor: Procedures

Brake Pedal Position Sensor Calibration

Calibration Criteria

Important: Do not apply the brake pedal during the brake pedal position sensor calibration procedure. Any movement of the brake pedal
during this procedure will cause the calibration procedure to fail. If this occurs, the brake pedal position sensor calibration must be repeated.

Brake pedal position sensor calibration must be performed after the brake pedal position sensor or body control module (BCM) have been serviced. The
calibration procedure will set brake pedal position sensor home value. This value is used by the BCM to determine the action of the driver applying the
brake system and to provide this information to the vehicle subsystems via the GMLAN communication bus.

Calibration Procedure

1.  Apply the parking brake.
2.  Place the transmission in the PARK position for automatic transmission or NEUTRAL for manual transmission.
3.  Install a scan tool.
4.  Clear all BCM DTCs before proceeding.
5.  Turn ON the ignition, with the engine OFF.
6.  Navigate to the BCM menu.
7.  Select Module Setup menu item.
8.  Select BPP Sensor Calibration procedure and follow the directions displayed on the screen.

Procedures|Page 784 > < Pedal Positioning Sensor|Diagrams