Torrent FWD V6-3.4L (2007)
1. Install the air inlet assembly.
Notice: Refer to Fastener Notice.
2. Install the air inlet assembly screws.
Tighten the screws to 1.5 N.m (13 lb in).
3. Install the recirculation actuator.
4. Install the recirculation actuator screws.
Tighten the screws to 1.5 N.m (13 lb in).
5. Install the electrical connector to the recirculation actuator.
6. Install the HVAC module.