Trans Sport V6-191 3.1L (1990)
Compressor Control Valve Assembly: Service and Repair
Remove or Disconnect
1. Discharge the Refrigerant System.
2. Remove control valve retaining ring using J-5403 internal snap ring pliers.
3. Remove control valve assembly.
Install or Connect
1. When reassembling control valve, coat O-ring with 525 viscosity refrigeration oil and push ii place with thumb pressure.
2. Using J-5403 snap ring pliers, install valve retaining ring with high point of curved side; against valve housing. Be sure retaining ring is properly
seated in ring groove. Leak test per procedure.