pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Recalls: > < Technical Service Bulletins|Locations|Page 7096
Page 1
background image

Air Door Actuator / Motor: Service and Repair

RECIRCULATION ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the Instrument Panel (IP) compartment.
2. Remove the connector (2).
3. Remove the two screws (1) and the air inlet actuator (3) from the HVAC module.

INSTALLATION PROCEDURE

1. Install the air inlet actuator (3) to the air inlet door shaft. The actuator can be installed on the shaft in two positions 180 degrees from each other.

Ensure that the door is in the correct position for the actuator. Secure with the two screws (1).

2. Install the connector (2).
3. Install the Instrument Panel (IP) compartment.

Recalls: > < Technical Service Bulletins|Locations|Page 7096