Air Injection Vacuum Control Solenoid Valve: Service and Repair

AUXILIARY INTAKE AIR CONTROL SOLENOID REPLACEMENT

REMOVAL PROCEDURE

1. Disconnect the electrical connector to the auxiliary intake air control solenoid (3).
2. Disconnect the 2 vacuum lines (2) to the auxiliary intake air control solenoid (3).
3. Remove the two fasteners (4) and the auxiliary intake air control solenoid (3) from the air cleaner housing.

INSTALLATION PROCEDURE

1. Install the auxiliary intake air control solenoid (3) to the air cleaner housing with the two fasteners (4).

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten
Tighten the fasteners to 3.7 N.m (33 lb in).

2. Connect the 2 vacuum hoses (2) to the auxiliary intake air control solenoid (3).
3. Connect the electrical connector.

Catalytic Converter > < Air Injection Vacuum Control Solenoid Valve|Locations