Vibe AWD L4-2.4L (2009)
8. Select: Vibe Programming Application.
9. Select: Vibe Programming.
10. The Calibration Update Wizard-Screen S701-02 box will appear.
1. Click: File Open.
2. An Insert disk box will appear. Click: Cancel.
11. The Calibration Update Wizard-Screen S701-12 box will appear.
1. Select: Desktop in the: Look in field.
2. Select: Pontiac Vibe folder and click: Open.
3. The Look in field will change to: Pontiac Vibe.
12. The Calibration Update Wizard-Screen S701-06 box will appear (Connect to Vehicle).
1. At the select MDI or J-2534 device Tool , select: ETAS MDI in the drop down menu.
2. Click: Next.
13. The Calibration Update Wizard-Screen S701-08 box will appear (Establishing communication with the vehicle). The Device Explorer box will
appear, listing all the available MDIs.
1. In the Device Explorer box, select the: MDI that is configured to the PC and is connected to the vehicle.
2. Click: Next.
14. The Calibration Update Wizard-Screen S701-09 box will appear (Calibration Selection Confirmation).
1. Review all of the information in this box.
2. Click: Next.
15. The Calibration Update Wizard-Screen S701-47 box will appear (Verify Calibration ID Numbers).
1. Review all of the information in this box.
2. Click: the old calibration under the Target Cal ID column.
3. Click: Next.
16. The Calibration Update Wizard-Screen S701-14 box will appear (Vehicle Preparation).
1. Review all of the information in this box.
2. Turn OFF the ignition.
3. Click: Next.
17. The Calibration Update Wizard-Screen S701-15 box will appear (Prepare for Reprogramming).
1. Review all of the information in this box.
2. Turn ON the ignition, with the engine OFF.
3. Click: Start.
18. The Calibration Update Wizard-Screen S701-17 box will appear (Flash Calibration Update in Process).
Wait for the update process to complete.
19. The Calibration Update Wizard-Screen S701-22 box will appear (Flash Calibration Update Successful).
1. Review all of the information in this box.
2. Turn OFF the ignition.
3. Click: Next.
20. The Calibration Update Wizard-Screen S701-23 box will appear (Prepare for verifying vehicle).
1. Review all of the information in this box.
2. Turn ON the ignition with the engine OFF.
3. Click: Next.
21. The Calibration Update Wizard-Screen S701-25 box will appear (Establishing communication with the vehicle).
1. The Calibration Update Wizard will verify the calibration that is currently in the vehicle.
2. Wait for the process to complete.
22. The Calibration Update Wizard-Screen S701-26 box will appear: Programming Successful!.