porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Procedures|Page 4453 > < Procedures
Page 2
background image

Releasing electric connectors

2. Release the electrical -a- and pull off.

Installing air-conditioning system regulator

Plugging in electric connector

1. Insert electrical plugs in the air-conditioning system regulator until they are felt to engage.

Sliding in air-conditioning system regulator

2. Slide the air-conditioning system regulator into the installation slot until it clicks into place.

Subsequent work

Subsequent work for the air-conditioning system regulator
1. Install left and right side cover for centre console.

Coding air-conditioning regulator

NOTE:  If the control unit for the air-conditioning control is replaced, it must be programmed using the PIWIS Tester 9718. This is to adapt the
control unit to the vehicle and equipment.

During coding, it is essential to guarantee the power supply for the PIWIS Tester 9718. It is essential to connect a battery charger with a current rating
of at least 40 A to the vehicle battery.

The PIWIS Tester 9718 instructions take precedence and in the event of a discrepancy these are the instructions that must be followed. Deviations
may occur with later software versions.

The procedure described here has been structured in general terms; different text or additions may appear in the Porsche System Tester.

1. Connect the PIWIS Tester 9718 to the vehicle and start the System Tester. Switch on ignition. ">>"continue.
2. Select vehicle type using the cursor keys. ">>"continue.
3. Select air conditioner with the cursor keys and press the ">>"key.
4. Select Control unit replacement with the cursor keys and press the ">>"key.
5. Select Read out values (codings) with the cursor keys and press the ">>"key.
6. The message Codes successfully read out appears on the screen of the Porsche System Tester. Press ">>".
7. Switch off ignition, replace air conditioning control.
8. Switch to the Special functions menu and perform the vehicle handover using the "F8" key.
9. In the Special functions menu, erase All fault memories by pressing ">>".

10. Carry out automatic search of control units.

Procedures|Page 4453 > < Procedures