Jump Starting: Service and Repair
Electrical Emergency Release For Lid

Electrical Emergency Release For Lid

NOTE:

-

In the event of a flat battery, the release motors of both lids can be supplied with power through the power feed via a battery jump lead.

-

An emergency power contact, colored red for identification, is located on the fuse box in the driver's footwell.

-

This emergency power contact, to which the positive jump lead is connected, can be pulled out of the fuse box by approx. 3 cm.

-

The power supply is switched to the release motors by a change-over relay (mini-relay), located behind the fuse box.

-

If the vehicle is locked (alarm protected), the alarm will sound if the jumper lead is connected.

-

Turn off alarm system by locking and then unlocking the door lock.

1. Unlock the vehicle at the door lock with the key.
2. Remove lid on fuse box and pull emergency power contact out of the fuse box.

3. Connect the red jumper lead (positive) to this contact.

4. Connect second (negative) jump lead to vehicle ground (e.g. to the lock striker on the B-pillar).
5. Connect jumper leads to an appropriate power source (e.g. separate vehicle battery).
6. Actuate the lid switch on the sill cover and open the lid.
7. Disconnect jumper leads and push the emergency power contact back in.
8. Clip cover back onto the fuse box.