porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Blower Motor > < Air Door, HVAC|Adjustments
Page 2
background image

2. Press temperature mixing flap to "max. cold" position. Linkage and lever must be in a straight line.
3. Correct deviation in length by turning the ball socket on the linkage.

Adjusting Footwell Flaps
1. Run motor to "footwell flaps closed" final position by supplying 12 volts to pin 4 (negative) and pin 5 (positive) via two electric leads until the

motor is in final position. Lever of drive faces in direction of fresh air inlet.

2. Move both footwell flaps into closed position. Engage linkage on the lever and secure with a clamp.

Blower Motor > < Air Door, HVAC|Adjustments