Fault code 38

Replace display and operator control unit.

Test point 20

Video interface
Value range

Fault code 39

Replace display and operator control unit.

Test point 21

Fault, memory interface
Value range

Fault code 40

Replace display and operator control unit.

Test point 22

Fault, photo sensor
Control module faulty
Value range

Fault code 41

Replace display and operator control unit.

Erase Fault Memory

Erasing fault memory

NOTE:  The fault memory can be erased only if it was first read out at least once.
The entire fault memory is always erased.

Actual Values

Actual Values

Values currently under test can be read out via this menu item.
The following values (setpoints in brackets) can be called up:

-

Speed

-

Current fuel consumption

-

photo transistor PCM (0-255) 

0 : Maximum brightness

255 : Minimum brightness

-

Date

-

Time

-

Dial, left [volume control] (up/down-counter)

-

Dial, right [selection knob] (up/down-counter)

* The counter is set to zero after the start of diagnosis. The counter is incremented by one when the dial is turned clockwise and decremented by one
when the dial is turned counter-clockwise.

Input Signals

Input Signals

Input signals of the PCM can be read in with this menu item. This allows the function of the input signals to be assessed very quickly.