porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Instrument Cluster Diagnosis - System K22, K23, K27|Page 5605 > < Instrument Cluster Diagnosis - System K22, K23, K27|Page 5603
Page 3
background image

Function Of The Components

Gateway

Gateway

The gateway is integrated in the PCM2. Together with the MMI, it is a fixed component of each PCM2. It provides a connection to CAN comfort via its
nodes. Diagnostic and useful data is exchanged with the CAN via these nodes. It creates links to the following systems:

-

CAN comfort

-

Media Oriented Systems Transport (MOST), internal (electrical)

-

Voice control system (VOCS) (optional/insertion)

-

Navigation (optional/insertion)

-

Man Machine Interface (MMI)

-

Single CD

-

Media Oriented Systems Transport (MOST), external bus (optical)

Internal Amplifier

Internal Amplifier

The internal amplifier is an optional part of the PCM2/CDR23 (installed on the main board).

Man Machine Interface (MMI)

Man Machine Interface (MMI)

The MMI is part of the PCM2 (on the main board). It carries out the diagnostics of the ring break diagnosis line (stub cable) and the diagnostics of the
optical distribution line.

MOST - Optical/Electrical

MOST - Optical/Electrical

MOST signals are transferred electrically within the PCM/CDR23 and optically outside of the PCM/CDR23. Internally, the PCM2 consists of at least 2
nodes (GW and MMI), which are installed in the device and can also be expanded to four nodes by adding the navigation and VOCS nodes (optional).
Internally, the CDR23 consists of one node (GW) which is installed in the CDR23.

The data is transferred outside of the PCM2 via the optical waveguide, which creates a connection to the nodes in the external MOST control modules
such as external amplifiers, CD changers, and/or telephone/telematics (optional, depending on the equipment). The data is transferred outside of the
CDR23 via the optical waveguide, which creates a connection to the nodes in the external MOST control modules such as external amplifiers and/or CD
changers (depending on the equipment). The gateway node represents the connection to CAN comfort.

MOST Actual and Required Installed Components Lists

MOST Actual And Required Installed Components Lists

All MOST control modules that are connected to the PCM2 are entered via diagnostic tester in the 'required installed components list'. Only the MOST
control modules recorded in the MOST required installed components list are activated. An 'actual installed components list' of detected devices is
written and saved when the PCM2 is started.

MOST Lock/MOST Unlock

MOST lock/MOST unlock

A lock occurs when the signal sent from the MMI via the MOST optical/electrical is understood and answered by the connected MOST control modules.
This applies a correct optical MOST signal. The lock is maintained until the signal is no longer detectable for a long period of time (several seconds)
'unlock'.

NOTE:  The 'Reset all coding/transmission counters' function can be used to reset all fault counters that were set for all components to '0'.

MOST Switch

MOST Switch

The MOST switch is part of the PCM2. It keeps the electrical MOST closed if no other MOST control module is optically connected to the MOST. The
MOST switch is opened when a light signal is received from the connected MOST control modules.

The following settings can be coded:

-

MOST switch open

Instrument Cluster Diagnosis - System K22, K23, K27|Page 5605 > < Instrument Cluster Diagnosis - System K22, K23, K27|Page 5603