Lateral Accelerometer: Testing and Inspection

Notes on the test 

The purpose of the test is to ensure the following points:
-

correct installation position of the sensor

-

functioning of the sensor

1. Connect Porsche System Tester 2. The diagnostic socket (arrow/Figure above) to which the Porsche System Tester 2 is connected is located in the

driver's footwell (left-hand drive vehicles) or passenger's footwell (right-hand drive vehicles) near the fuse box.

2. Select the "Actual values" menu/ "Transverse accel. sensor" sub-menu with the Porsche System Tester 2 in the PSM system. Entry to the PSM

system takes place through the ABS system (automatic status change after PSM).

3. Check and note or store the value of the transverse acceleration sensor in the normal position of the vehicle. Nominal value: 0.0 m/s2 ± 0.4 m/s2.

Note:  Normal position means: Vehicle on level surface. If the vehicle was raised beforehand, relieve the wheel suspensions if necessary (move the
vehicle a few meters as well as rocking it up and down at the front and rear a few times). If a value other than the nominal value is displayed, an
open circuit is present in the lead route or the transverse acceleration sensor is faulty.

4. Raise vehicle on the left at the jacking points until approximately 100 mm ground clearance is present at the left wheels. Read off and note or

store the value of the sensor in the PST 2 display.

Note:  Observe the safety regulations when raising the vehicle.

5. Lower vehicle on the left again. Then raise vehicle on the right in the same manner until approximately 100 mm ground clearance is present at the

right wheels. Read off and note or store the value of the sensor in the PST 2 display.

6. Carry out evaluation according to the following text. Eliminate faults present if necessary.

Nominal value: 

Raised on left approximately 100 mm 0.55 m/s2 or greater
Raised on right approximately 100 mm - 0.55 m/s2 or greater

Sensor function 

To check the vehicle, raise it once on the left and once on the right, approximately 100 mm each time.
An exactly defined change from the transverse acceleration value must take place. The output value is used as a reference value for vehicles placed on
a level surface.

Nominal display 

Lateral Accelerometer|Locations|Page 4396 > < Lateral Accelerometer|Locations