17. Loosen battery positive connection at the current distributor and current distributor at the firewall cover.
18. Clamp shut both heater hoses in front of the heat exchanger with a commercially available hose clamp. Disconnect the heating hoses on the heat

exchanger and plug the connections.

19. Undo heater/air-conditioning unit on the lid firewall (3 nuts). Pull off the water drainage hose from the heater/air-conditioning unit.

20. Undo holder of the heater/air-conditioning unit from the passenger's side at the top right.
21. Carefully lower and remove the heater/air-conditioning unit downwards into the footwell. Do not damage the electrical plug connections or cables.

Installation

1. Ensure that the air distributor casing and air guides are correctly positioned. Engage the electrical plug connections and carefully lay the electrical

cables (do not pinch).

2. Comply with safety regulations when handling airbag units (see Restraint Systems/Air Bag systems).  See: Restraint Systems/Air Bag Systems 

3. Set the steering column switch:

Measure with a depth gauge between end of steering shaft and steering-column switch cover plate.
Adjustment dimension 55 ± 0.5 mm

4. Replace gasket between current distributor and firewall if necessary. After the current distributor is mounted on the firewall (tightening torque 15

Nm (11 ftlb.)) the battery cable is tightened with a new hexagon nut M8. Tightening torque: 15 Nm (11 ftlb.)

5. Replace the O-rings for the refrigerant lines at the expansion valve and wet the new O-rings with refrigerant oil.

NOTE:  If the heating/air-conditioning unit is replaced, the refrigerant oil in the evaporator must be topped up. Determine the quantity of the refrigerant
oil and fill up again with refrigerant oil (volume removed by suction + 20 cu.cm).
Refrigerant oil removed from a previously run air-conditioning system may no longer be used (special-category waste).

Air Flow Control Box - A/C|Page 5230 > < Air Flow Control Box - A/C|Page 5228