porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Oxygen Sensor - Proper Care of Connections|Page 2911 > < Main Relay (Computer/Fuel System)|Locations|Page 2906
Page 1
background image

Oxygen Sensor: Technical Service Bulletins
Oxygen Sensor - Proper Care of Connections

911(996)
9902 2469

Binder - 2, Exhaust

10-22-99

Oxygen Sensor Connections

Vehicle Type:
911 Carrera (996)

Model Year:
As of 1999 (X)

Concern:
Proper care of oxygen sensor connections

Information:

Oxygen sensors perform their function by creating a signal voltage that is based on the comparison of air content in the exhaust system to that of a known
good air reference (ambient oxygen). Since 1989, the oxygen sensors on Porsche cars have been said to be "submersible". This means that the sampling
of reference oxygen is taken from the oxygen sensor connector in the engine compartment, as opposed to the oxygen sensor housing area (in prior
configurations). Taking reference air from the connector results in more accurate sensor readings, because the oxygen sensor connector is less likely to
be affected by moisture or foreign substances.

Although "submersible" oxygen sensors are basically impervious to substances at the sensor, they can be permanently damaged if any foreign substance
is sprayed or otherwise applied to the oxygen sensor connector (or signal wire). To function properly, reference air must be allowed to pass through the
connector, down the signal wire (within the insulation), and to the sensor.

Therefore, it is extremely important that the oxygen sensor connectors be clean and dry at all times. Contact cleaners, contact enhancers (such as
Stabilant 22A), oil or water based sprays, and even die-electric compounds MUST BE KEPT AWAY from the oxygen sensor connections, or permanent
SENSOR DAMAGE will result!

Always clean oxygen sensor contacts in a dry fashion, being careful not to allow any type of substance or debris into the connectors.

Note: 

The connections at the oxygen sensor can often be improved by simply unplugging and replugging the connector several times.

Important! 

Oxygen sensors damaged by the application of any foreign substance in the connector area will not be considered a warranty matter.

Please inform all service personnel immediately

Oxygen Sensor - Proper Care of Connections|Page 2911 > < Main Relay (Computer/Fuel System)|Locations|Page 2906